1.
Circ Cardiovasc Interv ; 10(8)2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28801540

RESUMO

BACKGROUND: The frequency of complex percutaneous coronary interventions (PCIs) has increased in the last few years, with a growing concern on the radiation dose received by the patients. Multicenter data from large unselected populations on patients' radiation doses during coronary angiography (CA) and PCI and temporal trends are lacking. This study sought to evaluate the temporal trends in patients' exposure to radiation from CA and PCI. METHODS AND RESULTS: Data were taken from the CARDIO-ARSIF registry that prospectively collects data on all CAs and PCIs performed in the 36 catheterization laboratories in the Greater Paris Area, the most populated regions in France with about 12 million inhabitants. Kerma area product and Fluoroscopy time from 152 684 consecutive CAs and 103 177 PCIs performed between 2009 and 2013 were analyzed. A continuous trend for a decrease in median [interquartile range] Kerma area product was observed, from 33 [19-55] Gy cm2 in 2009 to 27 [16-44] Gy cm2 in 2013 for CA (P<0.0001), and from 73 [41-125] to 55 [31-91] Gy cm2 for PCI (P<0.0001). Time-course differences in Kerma area product remained highly significant after adjustment on Fluoroscopy time, PCI procedure complexity, change of x-ray equipment, and other patient- and procedure-related covariates. CONCLUSIONS: In a large patient population, a steady temporal decrease in patient radiation exposure during CA and PCI was noted between 2009 and 2013. Kerma area product reduction was consistent in all types of procedure and was independent of patient-related factors and PCI procedure complexity.


Assuntos
Angiografia Coronária/tendências , Intervenção Coronária Percutânea/tendências , Doses de Radiação , Sistema de Registros , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada
2.
Prehosp Emerg Care ; 21(6): 782-785, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28622069

RESUMO

Spontaneous coronary artery dissection (SCAD) is an uncommon disease. We report the case of a 50 year-old woman with a past medical history of aneurysmal subarachnoid hemorrhage, presenting with acute chest pain and diffuse ST segment elevation on ECG. Coronary angiogram revealed a SCAD of the left anterior descending coronary artery. The association between cerebral aneurysms and SCAD should trigger providers concern for fibromuscular dysplasia. We hereby report on a rare and atypical case involving the relationship between fibromuscular dysplasia and SCAD.


Assuntos
Anomalias dos Vasos Coronários/diagnóstico , Anomalias dos Vasos Coronários/etiologia , Displasia Fibromuscular/complicações , Hemorragia Subaracnóidea/complicações , Doenças Vasculares/congênito , Dor no Peito , Angiografia Coronária , Serviços Médicos de Emergência , Feminino , Humanos , Pessoa de Meia-Idade , Doenças Vasculares/diagnóstico , Doenças Vasculares/etiologia
3.
Radiat Prot Dosimetry ; 175(1): 17-25, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27624893

RESUMO

The objective of this study was to estimate the French national updated reference levels (RLs) for coronary angiography (CA) and percutaneous coronary intervention (PCI) by a dose audit from a large data set of unselected procedures and in standard-sized patients. Kerma-area product (PKA), air kerma at interventional point (Ka,r), fluoroscopy time (FT), and the number of registered frames (NFs) and runs (NRs) were collected from 51 229 CAs and 42 222 PCIs performed over a 12-month period at 61 French hospitals. RLs estimated by the 75th percentile in CAs and PCIs performed in unselected patients were 36 and 78 Gy.cm² for PKA, 498 and 1285 mGy for Ka,r, 6 and 15 min for FT, and 566 and 960 for NF, respectively. These values were consistent with the RLs calculated in standard-sized patients. The large difference in dose between sexes leads us to propose specific RLs in males and females. The results suggest a trend for a time-course reduction in RLs for interventional coronary procedures.


Assuntos
Angiografia Coronária , Fluoroscopia , Doses de Radiação , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea , Radiografia Intervencionista
4.
Arch Cardiovasc Dis ; 107(4): 225-35, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24794216

RESUMO

BACKGROUND: Dual antiplatelet therapy, comprising aspirin and clopidogrel, is recommended in patients undergoing coronary stenting to avoid the occurrence of stent thrombosis and others ischaemic events. Interindividual response to clopidogrel varies, however, with poor response associated with an increased risk of ischaemic events. New assays are available for testing aspirin and clopidogrel response routinely at the bedside. AIM: To evaluate the prognostic value of testing antiplatelet response in an intermediate-risk population undergoing stent implantation. METHODS: We prospectively assessed clopidogrel and aspirin response using the VerifyNow assay at the time of coronary stenting in 1001 patients who presented with stable coronary disease or non-ST-segment elevation acute coronary syndrome. The main ischaemic endpoint was the composite of definite and probable stent thrombosis, cardiovascular death or spontaneous myocardial infarction at one year. The safety endpoint was major bleeding. RESULTS: Overall, 36.0% of patients had high on-clopidogrel platelet reactivity (OCR) and 8.6% had high on-aspirin platelet reactivity (OAR). The main ischaemic composite endpoint occurred in 3.9% of patients with high vs. 2.3% of patients with normal OCR (hazard ratio 1.66, 95% confidence interval 0.78-3.54; P=0.18). Definite or probable stent thrombosis occurred in 1.1% of patients with high vs. 0.3% of patients with normal OCR (P=0.86). There was no significant difference in ischaemic endpoints according to OAR and there was no difference in rates of major bleeding between patients with high versus normal on-treatment platelet reactivity. CONCLUSIONS: On-treatment platelet reactivity was not associated with 1-year ischaemic or bleeding events in an intermediate-risk population undergoing stent implantation.


Assuntos
Aspirina/uso terapêutico , Trombose Coronária/prevenção & controle , Hemorragia/induzido quimicamente , Intervenção Coronária Percutânea/instrumentação , Inibidores da Agregação Plaquetária/uso terapêutico , Testes de Função Plaquetária , Stents , Ticlopidina/análogos & derivados , Idoso , Aspirina/efeitos adversos , Clopidogrel , Trombose Coronária/diagnóstico , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Quimioterapia Combinada , Feminino , França , Hemorragia/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/prevenção & controle , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Ticlopidina/efeitos adversos , Ticlopidina/uso terapêutico , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 84(5): 766-71, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-23982995

RESUMO

AIMS: To compare the efficacy of three vasodilators in preventing radial artery spasm (RAS) in patients undergoing transradial percutaneous coronary interventions (PCI). METHODS AND RESULTS: 731 patients were randomized to receive diltiazem 5 mg, verapamil 2.5 mg, or isosorbide dinitrate (ISDN) 1 mg before coronary intervention. RAS occurred in 20.1% in the whole population and was significantly reduced by verapamil and ISDN compared to diltiazem (16.2, 17.2, and 26.6%, respectively; P < 0.006). There was also a trend towards less severe pain (more than 8 on a numerical scale from 0 [no pain] to 10 [maximal pain]), and less severe RAS (complete catheter blockage or severe pain), among patients treated by verapamil compared to ISDN and diltiazem (1.3% vs. 2.8% vs. 2.9%, P = 0.43 and 5.1% vs. 6.2% vs. 9.5%, respectively, P = 0.13). No difference was found between the three vasodilators in terms of crossover or safety events. Female gender, failure at first attempt to access the radial artery, emergency procedures, and the use of diltiazem were independent predictors of RAS. CONCLUSION: Verapamil and ISDN considerably reduce the incidence of RAS compared to diltiazem during transradial PCI.


Assuntos
Angioplastia Coronária com Balão/métodos , Diltiazem/administração & dosagem , Dinitrato de Isossorbida/administração & dosagem , Artéria Radial/efeitos dos fármacos , Espasmo/prevenção & controle , Verapamil/administração & dosagem , Idoso , Análise de Variância , Cateterismo Cardíaco/métodos , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Feminino , Seguimentos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Prospectivos , Resultado do Tratamento , Vasoconstrição/efeitos dos fármacos , Vasodilatadores/administração & dosagem
8.
Eur Heart J Acute Cardiovasc Care ; 1(1): 75-8, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24062892

RESUMO

Aspirin is key to the treatment of acute myocardial infarction, particularly if stent implantation is considered. In patients with a history of hypersensitivity to aspirin, the optimal management of ST-segment elevation acute myocardial infarction is unclear. We suggest a strategy for addressing this problem by performing percutaneous coronary intervention with antiplatelet therapy by intravenous glycoprotein IIb/IIIa receptor blockers and performing rapid oral desensitization in the ensuing hours, once the patient has stabilized.

11.
EuroIntervention ; 6(2): 247-50, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20562076

RESUMO

AIMS: To evaluate the feasibility and safety of an anticoagulation adapted regimen for transradial coronary angiography. METHODS AND RESULTS: We randomly assigned 162 consecutive patients who benefited from an elective transradial approach for coronarography to receive either a standard dose of 5,000 IU heparin or 50 IU/kg with an upper limit of 5,000 IU. Patients under anti-vitamin K therapy were excluded. The TRband compression system was employed for the entire population after the procedure. Radial artery patency, the primary endpoint, was evaluated with Doppler before discharge from the hospital. Secondary endpoints were: ACT level immediately before sheath removal, compression length and bleeding complications. Both groups were well matched. ACT level is significantly lower in the adjusted anticoagulation group (231.4 min, vs. 265.6 min, p<10-4). Radial compression time was higher in the standard protocol group (235.5 min, vs. 204.5 min, p<10-5). No radial occlusion was noted, whatever the group considered. Local haematoma is less frequent in the 50 IU/kg group, with no statistical difference. CONCLUSIONS: A weight-adjusted heparin dose allows for lower ACT levels and decreases in radial compression time without increase in radial artery occlusion. The impact on bleeding complication needs further evaluation in larger series.


Assuntos
Anticoagulantes/administração & dosagem , Angiografia Coronária/métodos , Heparina/administração & dosagem , Artéria Radial , Idoso , Peso Corporal , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS